SORA

Advancing, promoting and sharing knowledge of health through excellence in teaching, clinical practice and research into the prevention and treatment of illness

Precision, prognosis, and clinical performance of rounded and trabecular segmentation of cine cardiovascular magnetic resonance

Joy, G; Moon, JC; Punjabi, K; Alzahir, M; Artico, J; Shiwani, H; Pierce, I; Bhuva, A; Thakur, D; Xue, H; et al. Joy, G; Moon, JC; Punjabi, K; Alzahir, M; Artico, J; Shiwani, H; Pierce, I; Bhuva, A; Thakur, D; Xue, H; Kellman, P; Schelbert, E; Treibel, TA; Manisty, C; Davies, RH (2026) Precision, prognosis, and clinical performance of rounded and trabecular segmentation of cine cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance, 28 (1). p. 102014. ISSN 1097-6647 https://doi.org/10.1016/j.jocmr.2025.102014
SGUL Authors: Joy, George

[img] PDF Published Version
Available under License Creative Commons Attribution.

Download (8MB)
[img] Microsoft Word (.docx) (Supplementary material) Supporting information
Download (5MB)

Abstract

BACKGROUND: Measurements of cardiac size and function drive clinical decisions. Left ventricular (LV) metrics can be derived from cardiac MR images by delineating the blood pool and myocardium, by either drawing a rounded contour to approximate the compacted myocardial border, or by delineating the papillary muscles and trabeculae (trabecular segmentation). There is no consensus as to which is best, particularly in the emergent AI era. We developed machine-learning (ML) approaches for both and compared them for clinically important metrics (error rate, precision, and prognosis). METHODS: Separate ML models were developed for rounded and trabecular segmentation, using U-net models trained on 1923 subjects (mixed pathology, multiple scanners, multiple centers). Blood and myocardial volumes for each segmentation method were compared on 4118 healthy UK biobank subjects. Model segmentation quality was evaluated subjectively on a real-world clinical dataset of 1594 consecutive CMR scans, with all scans included regardless of image quality and artifacts. Scan-rescan precision was measured on a multi-center, multi-disease dataset of 109 subjects scanned twice and compared to human performance. Finally, prognostication ability was evaluated on 1215 clinical patients, using a primary outcome of all-cause mortality and hospitalization with heart failure. RESULTS: Error rates (where a human disagreed by >1 mL) were the same, occurring in 0.6% (184/29680) of images and 3.6% (60/1594) of patients. In health, the mean EF was 4% higher for trabecular vs rounded segmentation. On test-retest data, there was no difference between rounded and trabecular ML models for precision, apart from end-diastolic and end-systolic volume, which was better for rounded segmentations. ML rounded and trabecular precision exceeded clinician performance for EF. There were marginal differences in prognostication between rounded and trabecular models. CONCLUSION: We developed an automated method for annotating papillary muscles and trabeculae from cardiac MR images with low error rates. We found higher precision than clinicians in ejection fraction. There was similar precision and prognostication to an ML rounded model with similarly low error rates. Findings support the feasibility of automated trabecular segmentation in clinical care and clinical trials.

Item Type: Article
Additional Information: © 2025 The Author(s). Published by Elsevier Inc. on behalf of Society for Cardiovascular Magnetic Resonance. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Keywords: Artificial intelligence, Cardiac MRI, Rounded, Segmentation, Trabecular
SGUL Research Institute / Research Centre: Academic Structure > Cardiovascular & Genomics Research Institute
Journal or Publication Title: Journal of Cardiovascular Magnetic Resonance
ISSN: 1097-6647
Language: en
Media of Output: Print-Electronic
Related URLs:
Publisher License: Creative Commons: Attribution 4.0
Projects:
Project IDFunderFunder ID
AA/18/6/34223British Heart Foundationhttp://dx.doi.org/10.13039/501100000274
FS/19/35/34374British Heart Foundationhttp://dx.doi.org/10.13039/501100000274
FS/18/21/33447British Heart Foundationhttp://dx.doi.org/10.13039/501100000274
Dates:
Date Event
2026-01-06 Published
2025-11-25 Published Online
2025-11-20 Accepted
URI: https://openaccess.sgul.ac.uk/id/eprint/118263
Publisher's version: https://doi.org/10.1016/j.jocmr.2025.102014

Actions (login required)

Edit Item Edit Item