SORA

Advancing, promoting and sharing knowledge of health through excellence in teaching, clinical practice and research into the prevention and treatment of illness

Brief Report: Point of Care Cryptococcal Antigen Screening: Pipetting Finger-Prick Blood Improves Performance of Immunomycologics Lateral Flow Assay.

Wake, RM; Jarvis, JN; Harrison, TS; Govender, NP (2018) Brief Report: Point of Care Cryptococcal Antigen Screening: Pipetting Finger-Prick Blood Improves Performance of Immunomycologics Lateral Flow Assay. J Acquir Immune Defic Syndr, 78 (5). pp. 574-578. ISSN 1944-7884 https://doi.org/10.1097/QAI.0000000000001721
SGUL Authors: Harrison, Thomas Stephen

[img] Microsoft Word (.docx) Accepted Version
Available under License ["licenses_description_publisher" not defined].

Download (55kB)
[img] Microsoft Word (.docx) (Table 1) Accepted Version
Available under License ["licenses_description_publisher" not defined].

Download (20kB)
[img]
Preview
Image (TIFF) (Figure 1) Accepted Version
Available under License ["licenses_description_publisher" not defined].

Download (255kB) | Preview
[img]
Preview
Image (TIFF) (Supplementary Figure 1) Accepted Version
Available under License ["licenses_description_publisher" not defined].

Download (275kB) | Preview
[img]
Preview
Image (TIFF) (Supplementary Figure 2) Accepted Version
Available under License ["licenses_description_publisher" not defined].

Download (477kB) | Preview
[img]
Preview
Image (TIFF) (Supplementary Figure 3) Accepted Version
Available under License ["licenses_description_publisher" not defined].

Download (432kB) | Preview

Abstract

BACKGROUND: Cryptococcal antigen (CrAg) screening at the point of care could improve cryptococcal meningitis prevention where laboratory resources are limited. We evaluated the accuracy of Immunomycologics (IMMY, Norman, OK) CrAg lateral flow assay (LFA) using different techniques at point of care. SETTING: Two tertiary-level hospitals in Johannesburg and a community health clinic in Soweto, South Africa. METHODS: A case-control diagnostic validation study and a prospective clinic-based implementation study using the IMMY CrAg LFA on finger-prick blood. Accuracy, using direct application of LFA to sample, or pipette to transfer sample to diluent, and reading after 10 and 20 minutes, was compared with laboratory-based plasma testing. RESULTS: The validation study tested 64 CrAg-positive and 152 CrAg-negative patients with no symptoms or signs of meningitis, identified by routine laboratory screening, recruited by convenience sampling. Consecutively diagnosed HIV-infected adults (n = 654) were included in the implementation study. Sensitivity was 82% and 20% when the LFA was read 10 minutes after direct application to finger-prick blood in the validation and implementation studies, respectively. Using a pipette to transfer blood and reading after 20 minutes improved sensitivity to 100%, while retaining 100% specificity, in both studies. CONCLUSIONS: Although the IMMY CrAg LFA performs well when applied directly to finger-prick blood for diagnosing cryptococcal meningitis, this technique may not provide adequate volume to detect low concentrations of CrAg when screening asymptomatic patients. Using a pipette to transfer larger volumes of blood to diluent before CrAg LFA testing and reading results after 20 minutes is a more reliable point-of-care method.

Item Type: Article
Additional Information: This is a non-final version of an article published in final form in Wake, RM; Jarvis, JN; Harrison, TS; Govender, NP (2018) Brief Report: Point of Care Cryptococcal Antigen Screening: Pipetting Finger-Prick Blood Improves Performance of Immunomycologics Lateral Flow Assay. J Acquir Immune Defic Syndr, 78 (5). pp. 574-578.
Keywords: Virology, 1103 Clinical Sciences
SGUL Research Institute / Research Centre: Academic Structure > Infection and Immunity Research Institute (INII)
Journal or Publication Title: J Acquir Immune Defic Syndr
ISSN: 1944-7884
Language: eng
Dates:
DateEvent
15 August 2018Published
30 April 2018Published Online
23 April 2018Accepted
Publisher License: Publisher's own licence
Projects:
Project IDFunderFunder ID
5R01AI118511-0National Institutes of Healthhttp://dx.doi.org/10.13039/100000002
PubMed ID: 29771787
Go to PubMed abstract
URI: https://openaccess.sgul.ac.uk/id/eprint/109962
Publisher's version: https://doi.org/10.1097/QAI.0000000000001721

Actions (login required)

Edit Item Edit Item