Li, A; Grimster, A; Saba, M
(2021)
Successful ablation of ventricular tachycardia in the presence of a novel self-expanding transcatheter mitral valve replacement.
HeartRhythm Case Rep, 7 (3).
pp. 131-133.
ISSN 2214-0271
https://doi.org/10.1016/j.hrcr.2020.11.018
SGUL Authors: Saba, Magdi Mohamed
|
PDF
Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives. Download (743kB) | Preview |
Item Type: | Article |
---|---|
Additional Information: | © 2020 Heart Rhythm Society. Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
Keywords: | Ablation, Intracardiac echocardiography, Percutaneous mitral valve, Tendyne valve, Ventricular tachycardia |
SGUL Research Institute / Research Centre: | Academic Structure > Molecular and Clinical Sciences Research Institute (MCS) |
Journal or Publication Title: | HeartRhythm Case Rep |
ISSN: | 2214-0271 |
Language: | eng |
Publisher License: | Creative Commons: Attribution-Noncommercial-No Derivative Works 4.0 |
PubMed ID: | 33786304 |
Go to PubMed abstract | |