SORA

Advancing, promoting and sharing knowledge of health through excellence in teaching, clinical practice and research into the prevention and treatment of illness

Day case complex devices: the state of the UK.

Waight, M; Elawady, A; Gage, H; Touray, M; Adhya, S (2019) Day case complex devices: the state of the UK. Open Heart, 6 (1). e001023. ISSN 2053-3624 https://doi.org/10.1136/openhrt-2019-001023
SGUL Authors: Waight, Michael Charles Staward

[img]
Preview
PDF Published Version
Available under License Creative Commons Attribution Non-commercial.

Download (1MB) | Preview

Abstract

Objective: Complex cardiac devices including implantable cardioverter defibrillator (ICD) and cardiac resynchronisation therapy (CRT) devices can safely be implanted as a day case procedure as opposed to overnight stay. We assess how common day case complex device therapy is and the cost implications of more widespread adoption across the UK. Methods: A freedom of information request was sent to all centres performing complex cardiac devices across the UK to assess the adoption of this technique. Cost implications were assessed using Department of Health National Schedule of Reference Costs 2016-2017. Results: 100 UK centres were surveyed, 80% replied. Eighty per cent of UK centres already implant complex cardiac devices as a day case to some extent. 64.06% of centres have a protocol for this. 12.82% of centres do <25% of complex devices as a day case. 15.38% do 25%-50% as day case. 17.95% do 50%-75% as day case and 33.33% do >75% as day case. There was no relationship between centre volume and the proportion of devices done as a day case as opposed to overnight stay. The cost saving of performing a complex device as a day case as opposed to overnight stay was £412 per ICD, £525 per CRT-pacemaker and £2169 per CRT-defibrillator. Conclusions: Day case complex devices are already widespread across the UK, however, there is scope for increase. An increase in proportion of day case devices could translate to £5 583 265 in savings annually for the National Health Service if all centres performed 75% of devices as a day case.

Item Type: Article
Additional Information: © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
Keywords: cardiology, complex cardiac devices, day case procedures, hospital economics
SGUL Research Institute / Research Centre: Academic Structure > Molecular and Clinical Sciences Research Institute (MCS)
Journal or Publication Title: Open Heart
ISSN: 2053-3624
Language: eng
Dates:
DateEvent
25 April 2019Published
25 March 2019Accepted
Publisher License: Creative Commons: Attribution-Noncommercial 4.0
PubMed ID: 31168388
Web of Science ID: WOS:000471922200072
Go to PubMed abstract
URI: https://openaccess.sgul.ac.uk/id/eprint/112938
Publisher's version: https://doi.org/10.1136/openhrt-2019-001023

Statistics

Item downloaded times since 11 Feb 2021.

Actions (login required)

Edit Item Edit Item