SORA

Advancing, promoting and sharing knowledge of health through excellence in teaching, clinical practice and research into the prevention and treatment of illness

Optical coherence tomography versus intravascular ultrasound to evaluate stent implantation in patients with calcific coronary artery disease.

Gudmundsdottir, I; Adamson, P; Gray, C; Spratt, JC; Behan, MW; Henriksen, P; Newby, DE; Mills, N; Uren, NG; Cruden, NL (2015) Optical coherence tomography versus intravascular ultrasound to evaluate stent implantation in patients with calcific coronary artery disease. Open Heart, 2 (1). e000225. ISSN 2053-3624 https://doi.org/10.1136/openhrt-2014-000225
SGUL Authors: Spratt, James

[img]
Preview
PDF Accepted Version
Available under License Creative Commons Attribution Non-commercial.

Download (778kB) | Preview

Abstract

AIMS: Stent underexpansion and malapposition are associated with adverse outcomes following percutaneous coronary intervention, but detection and treatment can be challenging in the presence of extensive coronary artery calcification. Frequency domain optical coherence tomography (FD-OCT) is a novel intravascular imaging technique with greater spatial resolution than intravascular ultrasound (IVUS) but its role in the presence of extensive coronary calcification remains unclear. We sought to determine the utility of FD-OCT compared to IVUS imaging to guide percutaneous coronary intervention in patients with severe calcific coronary artery disease. METHODS: 18 matched IVUS and FD-OCT examinations were evaluated following coronary stent implantation in 12 patients (10 male; mean age 70±7 years) undergoing rotational atherectomy for symptomatic calcific coronary artery disease. RESULTS: In-stent luminal areas were smaller (minimum in-stent area 6.77±2.18 vs 7.19±2.62 mm(2), p<0.05), while reference lumen dimensions were similar with FD-OCT compared with IVUS. Stent malapposition was detected in all patients by FD-OCT and in 10 patients by IVUS. The extent of stent malapposition detected was greater (20% vs 6%, p<0.001) with FD-OCT compared to IVUS. Postdilation increased the in-stent luminal area (minimum in-stent area: 8.15±1.90 vs 7.30±1.62 mm(2), p<0.05) and reduced the extent of stent malapposition (19% vs 34%, p<0.005) when assessed by FD-OCT, but not IVUS. CONCLUSIONS: Acute stent malapposition occurs frequently in patients with calcific coronary disease undergoing rotational atherectomy and stent implantation. In the presence of extensive coronary artery calcification, FD-OCT affords enhanced stent visualisation and detection of malapposition, facilitating improved postdilation stent apposition and minimal luminal areas. TRIAL REGISTRATION NUMBER: NCT02065102.

Item Type: Article
Additional Information: Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/ This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Keywords: INTERVENTIONAL CARDIOLOGY
SGUL Research Institute / Research Centre: Academic Structure > Molecular and Clinical Sciences Research Institute (MCS)
Journal or Publication Title: Open Heart
ISSN: 2053-3624
Language: eng
Dates:
DateEvent
23 December 2015Published
6 May 2015Accepted
Publisher License: Creative Commons: Attribution-Noncommercial 4.0
Projects:
Project IDFunderFunder ID
103782Wellcome Trusthttp://dx.doi.org/10.13039/100004440
PubMed ID: 26719807
Web of Science ID: WOS:000443090900039
Go to PubMed abstract
URI: https://openaccess.sgul.ac.uk/id/eprint/111680
Publisher's version: https://doi.org/10.1136/openhrt-2014-000225

Actions (login required)

Edit Item Edit Item