Khodakarami, H;
Ricciardi, L;
Contarino, MF;
Pahwa, R;
Lyons, KE;
Geraedts, VJ;
Morgante, F;
Leake, A;
Paviour, D;
De Angelis, A;
et al.
Khodakarami, H; Ricciardi, L; Contarino, MF; Pahwa, R; Lyons, KE; Geraedts, VJ; Morgante, F; Leake, A; Paviour, D; De Angelis, A; Horne, M
(2019)
Prediction of the Levodopa Challenge Test in Parkinson's Disease Using Data from a Wrist-Worn Sensor.
Sensors (Basel), 19 (23).
p. 5153.
ISSN 1424-8220
https://doi.org/10.3390/s19235153
SGUL Authors: Morgante, Francesca
Abstract
The response to levodopa (LR) is important for managing Parkinson's Disease and is measured with clinical scales prior to (OFF) and after (ON) levodopa. The aim of this study was to ascertain whether an ambulatory wearable device could predict the LR from the response to the first morning dose. The ON and OFF scores were sorted into six categories of severity so that separating Parkinson's Kinetigraph (PKG) features corresponding to the ON and OFF scores became a multi-class classification problem according to whether they fell below or above the threshold for each class. Candidate features were extracted from the PKG data and matched to the class labels. Several linear and non-linear candidate statistical models were examined and compared to classify the six categories of severity. The resulting model predicted a clinically significant LR with an area under the receiver operator curve of 0.92. This study shows that ambulatory data could be used to identify a clinically significant response to levodopa. This study has also identified practical steps that would enhance the reliability of this test in future studies.
Item Type: |
Article
|
Additional Information: |
© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Correction available at: https://doi.org/10.3390/s20154167 |
Keywords: |
Parkinson’s Disease, ambulatory systems, levodopa challenge test, levodopa response, machine learning, wearable devices, 0301 Analytical Chemistry, 0906 Electrical And Electronic Engineering, Analytical Chemistry |
SGUL Research Institute / Research Centre: |
Academic Structure > Molecular and Clinical Sciences Research Institute (MCS) |
Journal or Publication Title: |
Sensors (Basel) |
ISSN: |
1424-8220 |
Language: |
eng |
Dates: |
Date | Event |
---|
25 November 2019 | Published | 12 November 2019 | Accepted |
|
PubMed ID: |
31775289 |
|
Go to PubMed abstract |
URI: |
https://openaccess.sgul.ac.uk/id/eprint/111456 |
Publisher's version: |
https://doi.org/10.3390/s19235153 |
Statistics
Item downloaded times since 04 Dec 2019.
Actions (login required)
|
Edit Item |