Methodological consensus on clinical proton MRS of the brain: Review and recommendations

Wilson, M; Andronesi, O; Barker, PB; Bartha, R; Bizzi, A; Bolan, PJ; Brindle, KM; Choi, I-Y; Cudalbu, C; Dydak, U; et al. Wilson, M; Andronesi, O; Barker, PB; Bartha, R; Bizzi, A; Bolan, PJ; Brindle, KM; Choi, I-Y; Cudalbu, C; Dydak, U; Emir, UE; Gonzalez, RG; Gruber, S; Gruetter, R; Gupta, RK; Heerschap, A; Henning, A; Hetherington, HP; Huppi, PS; Hurd, RE; Kantarci, K; Kauppinen, RA; Klomp, DWJ; Kreis, R; Kruiskamp, MJ; Leach, MO; Lin, AP; Luijten, PR; Marjańska, M; Maudsley, AA; Meyerhoff, DJ; Mountford, CE; Mullins, PG; Murdoch, JB; Nelson, SJ; Noeske, R; Öz, G; Pan, JW; Peet, AC; Poptani, H; Posse, S; Ratai, E-M; Salibi, N; Scheenen, TWJ; Smith, ICP; Soher, BJ; Tkáč, I; Vigneron, DB; Howe, FA (2019) Methodological consensus on clinical proton MRS of the brain: Review and recommendations. Magn Reson Med, 82 (2). pp. 527-550. ISSN 1522-2594 https://doi.org/10.1002/mrm.27742
SGUL Authors: Howe, Franklyn Arron

[img]
Preview
PDF Accepted Version
Available under License ["licenses_description_publisher" not defined].

Download (1MB) | Preview
[img]
Preview
PDF (Supporting information) Accepted Version
Available under License ["licenses_description_publisher" not defined].

Download (6MB) | Preview

Abstract

Proton MRS (1H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good‐quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi‐adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use.

Item Type: Article
Additional Information: This is the peer reviewed version of the following article: Wilson, M, Andronesi, O, Barker, PB, et al. Methodological consensus on clinical proton MRS of the brain: Review and recommendations. Magn Reson Med. 2019; 82: 527– 550, which has been published in final form at https://doi.org/10.1002/mrm.27742. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.
Keywords: MRS, brain, consensus, metabolites, semi-LASER, shimming, 0903 Biomedical Engineering, Nuclear Medicine & Medical Imaging
SGUL Research Institute / Research Centre: Academic Structure > Molecular and Clinical Sciences Research Institute (MCS)
Journal or Publication Title: Magn Reson Med
ISSN: 1522-2594
Language: eng
Dates:
DateEvent
9 May 2019Published
28 March 2019Published Online
25 February 2019Accepted
Publisher License: Publisher's own licence
PubMed ID: 30919510
Go to PubMed abstract
URI: https://openaccess.sgul.ac.uk/id/eprint/110783
Publisher's version: https://doi.org/10.1002/mrm.27742