Molloholli, M;
Napolitano, R;
Ohuma, EO;
Ash, S;
Wanyonyi, SZ;
Cavallaro, A;
Giudicepietro, A;
Barros, F;
Carvalho, M;
Norris, S;
et al.
Molloholli, M; Napolitano, R; Ohuma, EO; Ash, S; Wanyonyi, SZ; Cavallaro, A; Giudicepietro, A; Barros, F; Carvalho, M; Norris, S; Min, MAM; Zainab, G; Papageorghiou, AT
(2019)
Image scoring system for umbilical and uterine artery pulsed wave Doppler ultrasound measurement.
Ultrasound Obstet Gynecol, 53 (2).
pp. 251-255.
ISSN 1469-0705
https://doi.org/10.1002/uog.19101
SGUL Authors: Papageorghiou, Aris
Preview |
|
PDF
Accepted Version
Available under License ["licenses_description_publisher" not defined].
Download (1MB)
| Preview
|
Abstract
Objectives
To develop an objective image‐scoring system for pulsed‐wave Doppler measurement of maternal uterine and fetal umbilical arteries, and evaluate how this compares with subjective assessment.
Methods
As an extension to the INTERGROWTH‐21st Project, we developed a scoring system based on six predefined criteria for uterine and umbilical artery pulsed‐wave Doppler measurements. Objective evaluation using the scoring system was compared with subjective assessment which consisted of classifying an image as simply acceptable or unacceptable. Based on sample size estimation, a total of 120 umbilical and uterine artery Doppler images were selected randomly from the INTERGROWTH‐21st image database. Two independent reviewers evaluated all images in a blinded fashion, both subjectively and using the six‐point scoring system. Percentage agreement and kappa statistic were compared between the two methods.
Results
The overall agreement between reviewers was higher for objective assessment using the scoring system (agreement, 85%; adjusted kappa, 0.70) than for subjective assessment (agreement, 70%; adjusted kappa, 0.47). For the six components of the scoring system, the level of agreement (adjusted kappa) was 0.97 for anatomical site, 0.88 for sweep speed, 0.77 for magnification, 0.68 for velocity scale, 0.68 for image clarity and 0.65 for angle of insonation.
Conclusion
In quality assessment of umbilical and uterine artery pulsed‐wave Doppler measurements, our proposed objective six‐point image‐scoring system is associated with greater reproducibility than is subjective assessment. We recommend this as the preferred method for quality control, auditing and teaching.
Item Type: |
Article
|
Additional Information: |
This is the peer reviewed version of the following article: Molloholli, M. , Napolitano, R. , Ohuma, E. O., Ash, S. , Wanyonyi, S. Z., Cavallaro, A. , Giudicepietro, A. , Barros, F. , Carvalho, M. , Norris, S. , Min, A. M., Zainab, G. and Papageorghiou, A. T. (2019), Image‐scoring system for umbilical and uterine artery pulsed‐wave Doppler ultrasound measurement. Ultrasound Obstet Gynecol, 53: 251-255, which has been published in final form at https://doi.org/10.1002/uog.19101. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. |
Keywords: |
Umbilical artery Doppler, Uterine artery Doppler, growth restriction, image scoring, quality control, reproducibility, Obstetrics & Reproductive Medicine, 1114 Paediatrics And Reproductive Medicine |
SGUL Research Institute / Research Centre: |
Academic Structure > Institute of Medical, Biomedical and Allied Health Education (IMBE) Academic Structure > Institute of Medical, Biomedical and Allied Health Education (IMBE) > Centre for Clinical Education (INMECE ) |
Journal or Publication Title: |
Ultrasound Obstet Gynecol |
ISSN: |
1469-0705 |
Language: |
eng |
Dates: |
Date | Event |
---|
5 February 2019 | Published | 28 May 2018 | Published Online | 22 May 2018 | Accepted |
|
Publisher License: |
Publisher's own licence |
Projects: |
|
PubMed ID: |
29808615 |
|
Go to PubMed abstract |
URI: |
https://openaccess.sgul.ac.uk/id/eprint/109877 |
Publisher's version: |
https://doi.org/10.1002/uog.19101 |
Statistics
Item downloaded times since 06 Jun 2018.
Actions (login required)
|