T2-Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE-prepared variable flip angle turbo spin echo readout (DANTE-SPACE).

Viessmann, O; Li, L; Benjamin, P; Jezzard, P (2017) T2-Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE-prepared variable flip angle turbo spin echo readout (DANTE-SPACE). Magn Reson Med, 77 (2). pp. 655-663. ISSN 1522-2594 https://doi.org/10.1002/mrm.26152
SGUL Authors: Benjamin, Philip

[img]
Preview
PDF Published Version
Available under License Creative Commons Attribution.

Download (2MB) | Preview

Abstract

PURPOSE: To optimize intracranial vessel wall imaging (VWI) at 7T for sharp wall depiction and high boundary contrast. METHODS: A variable flip angle turbo spin echo scheme (SPACE) was optimized for VWI. SPACE provides black-blood contrast, but has less crushing effect on cerebrospinal fluid (CSF). However, a delay alternating with nutation for tailored excitation (DANTE) preparation suppresses the signal from slowly moving spins of a few mm per second. Therefore, we optimized a DANTE-preparation module for 7T. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and signal ratio for vessel wall, CSF, and lumen were calculated for SPACE and DANTE-SPACE in 11 volunteers at the middle cerebral artery (MCA). An exemplar MCA stenosis patient was scanned with DANTE-SPACE. RESULTS: The 7T-optimized SPACE sequence improved the vessel wall point-spread function by 17%. The CNR between the wall and CSF was doubled (12.2 versus 5.6) for the DANTE-SPACE scans compared with the unprepared SPACE. This increase was significant in the right hemisphere (P = 0.016), but not in the left (P = 0.090). The CNR between wall and lumen was halved, but remained at a high value (24.9 versus 56.5). CONCLUSION: The optimized SPACE sequence improves VWI at 7T. Additional DANTE preparation increases the contrast between the wall and CSF. Increased outer boundary contrast comes at the cost of reduced inner boundary contrast.

Item Type: Article
Additional Information: © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Keywords: DANTE, SPACE, Vessel wall imaging, black-blood imaging, plaque imaging, stroke, variable flip angle, Nuclear Medicine & Medical Imaging, 0903 Biomedical Engineering
SGUL Research Institute / Research Centre: Academic Structure > Molecular and Clinical Sciences Research Institute (MCS)
Academic Structure > Molecular and Clinical Sciences Research Institute (MCS) > Neuroscience (INCCNS)
Journal or Publication Title: Magn Reson Med
ISSN: 1522-2594
Language: eng
Dates:
DateEvent
February 2017Published
18 February 2016Published Online
15 January 2016Accepted
Publisher License: Creative Commons: Attribution 4.0
Projects:
Project IDFunderFunder ID
G0700399Medical Research Councilhttp://dx.doi.org/10.13039/501100000265
PG/11/120/29302British Heart Foundationhttp://dx.doi.org/10.13039/501100000274
PubMed ID: 26890988
Go to PubMed abstract
URI: https://openaccess.sgul.ac.uk/id/eprint/108763