Relationship Between Distance and Change in Surface ECG Morphology During Pacemapping as a Guide to Ablation of Ventricular Arrhythmias: Implications for the Spatial Resolution of Pacemapping.
Circ Arrhythm Electrophysiol, 10 (1).
e004447.
ISSN 1941-3084
https://doi.org/10.1161/CIRCEP.116.004447
SGUL Authors: Behr, Elijah Raphael Li, Anthony Saba, Magdi Mohamed
Microsoft Word (.docx)
Accepted Version
Available under License ["licenses_description_publisher" not defined]. Download (516kB) |
Abstract
BACKGROUND: Pacemapping is used to localize the exit site of ventricular arrhythmia. Although the relationship between distance and change in QRS morphology is its basis, this relationship has not been systematically quantified. METHODS AND RESULTS: Patients (n=68) undergoing ventricular arrhythmia ablation between March 2012 and July 2013 were recruited. Pacemapping was targeted to areas of voltage >0.5 mV. Linear mixed-effects models were constructed of distance against morphology difference measured by the root mean square error sum across all 12 ECG leads (E12). Forty of 68 (58%) patients had structural heart disease, and 21/40 (53%) patients were ischemic. Nine hundred thirty-five pacing points were collected, generating 6219 pacing site pair combinations (3087 [50%] ventricular bodies, 756 [12%] outflow tract, and 162 [3%] epicardial). In multivariable analysis, increase in E12 was predicted by increasing distance (0.07 per mm; 95% confidence interval 0.07-0.08; P<0.001). Compared with the left ventricle, E12 values were lower in the right ventricle (P=0.037) and left ventricular outflow tract (P<0.001) and higher in left ventricle-right ventricle pairs (P=0.021) and left ventricular epicardium (P=0.08). There was no difference in E12 in the right ventricular outflow tract compared with the right-left ventricular outflow tract (P=0.75) pairs. Structural heart disease or inadvertent pacing in scar was not associated with changes in E12; however, the presence of latency and split potentials were associated with higher and lower E12 values, respectively (P<0.001). CONCLUSIONS: A robust positive relationship exists between distance and QRS morphological change when restricting pacing points to areas of voltage >0.5 mV. Significant differences in the spatial resolution of pacemapping exist within the heart.
Item Type: | Article | ||||||||
---|---|---|---|---|---|---|---|---|---|
Additional Information: | © 2016 American Heart Association, Inc. | ||||||||
Keywords: | catheter ablation, electrophysiology mapping, mapping, pacemapping, ventricular arrhythmia, ventricular tachycardia, Cardiovascular System & Hematology | ||||||||
SGUL Research Institute / Research Centre: | Academic Structure > Molecular and Clinical Sciences Research Institute (MCS) Academic Structure > Molecular and Clinical Sciences Research Institute (MCS) > Cardiac (INCCCA) |
||||||||
Journal or Publication Title: | Circ Arrhythm Electrophysiol | ||||||||
ISSN: | 1941-3084 | ||||||||
Language: | eng | ||||||||
Dates: |
|
||||||||
Publisher License: | Publisher's own licence | ||||||||
PubMed ID: | 28031213 | ||||||||
Go to PubMed abstract | |||||||||
URI: | https://openaccess.sgul.ac.uk/id/eprint/108485 | ||||||||
Publisher's version: | https://doi.org/10.1161/CIRCEP.116.004447 |
Statistics
Actions (login required)
Edit Item |