Control of Postpartum Hemorrhage Using Vacuum-Induced Uterine Tamponade.

Purwosunu, Y; Sarkoen, W; Arulkumaran, S; Segnitz, J (2016) Control of Postpartum Hemorrhage Using Vacuum-Induced Uterine Tamponade. Obstetrics & Gynecology, 128 (1). pp. 33-36. ISSN 0029-7844 https://doi.org/10.1097/AOG.0000000000001473
SGUL Authors: Arulkumaran, Sabaratnam

[img] Microsoft Word (.doc) Accepted Version
Available under License ["licenses_description_publisher" not defined].

Download (52kB)

Abstract

BACKGROUND: Postpartum hemorrhage is the leading cause of maternal mortality worldwide. Vacuum-induced uterine tamponade is a possible alternative approach to balloon tamponade systems for the treatment of postpartum hemorrhage resulting from atony. METHOD: In a prospective proof-of-concept investigation of 10 women with vaginal deliveries in a hospital setting who failed first-line therapies for postpartum hemorrhage, tamponade was used. Vacuum-induced uterine tamponade was created through a device inserted transvaginally into the uterine cavity. An occlusion balloon built into the device shaft was inflated at the level of the external cervical os to create a uterine seal. Negative pressure was created by attaching a self-contained, mobile, electrically powered, pressure-regulated vacuum pump with a sterile graduated canister. EXPERIENCE: In all 10 cases, the suction created an immediate seal at the cervical os, 50-250 mL of residual blood was evacuated from the uterine cavity, the uterus collapsed and regained tone within minutes, and hemorrhaging was controlled. The device remained in place for a minimum of 1 hour and up to 6.5 hours in one case while vaginal and perineal lacerations were easily repaired. CONCLUSION: This preliminary investigation suggests that a device designed to create vacuum-induced uterine tamponade may be a reasonable alternative to other devices used to treat atonic postpartum hemorrhage.

Item Type: Article
Additional Information: © by The American College of Obstetricians and Gynecologists. Published by Wolters Kluwer Health, Inc. This is a non-final version of an article published in final form in: Purwosunu, Yuditiya MD; Sarkoen, Widyastuti MD; Arulkumaran, Sabaratnam MD, PhD; Segnitz, Jan MD, Control of Postpartum Hemorrhage Using Vacuum-Induced Uterine Tamponade. Obstetrics & Gynecology. 128(1):33-36, July 2016.10.1097/AOG.0000000000001473
Keywords: Obstetrics & Reproductive Medicine, 1114 Paediatrics And Reproductive Medicine
SGUL Research Institute / Research Centre: Academic Structure > Molecular and Clinical Sciences Research Institute (MCS)
Academic Structure > Molecular and Clinical Sciences Research Institute (MCS) > Vascular (INCCVA)
Journal or Publication Title: Obstetrics & Gynecology
ISSN: 0029-7844
Language: eng
Dates:
DateEvent
1 July 2016Published
12 April 2016Accepted
Publisher License: Publisher's own licence
PubMed ID: 27275795
Web of Science ID: WOS:000379509800006
Go to PubMed abstract