SORA

Advancing, promoting and sharing knowledge of health through excellence in teaching, clinical practice and research into the prevention and treatment of illness

Mind the gap: avoiding paravalvular leak using computer simulation in bicuspid transcatheter aortic valve replacement-a case report.

Dargan, J; Hampal, R; Khan, F; Brecker, S (2022) Mind the gap: avoiding paravalvular leak using computer simulation in bicuspid transcatheter aortic valve replacement-a case report. Eur Heart J Case Rep, 6 (10). ytac398. ISSN 2514-2119 https://doi.org/10.1093/ehjcr/ytac398
SGUL Authors: Brecker, Stephen

[img]
Preview
PDF Published Version
Available under License Creative Commons Attribution Non-commercial.

Download (691kB) | Preview
[img] Microsoft PowerPoint (Supplementary Data) Published Version
Available under License Creative Commons Attribution Non-commercial.

Download (4MB)

Abstract

Background: Transcatheter aortic valve replacement (TAVR) is becoming increasingly prevalent worldwide and is now more common than surgical aortic valve replacement. It is expanding into all patient subsets including younger and lower risk patients. Bicuspid aortic valve (BAV) accounts for a significant proportion of TAVR, but due to heterogenous anatomy, it is of increased complexity. One of the greatest challenges in BAV is the selection of the correct TAVR size. Transcatheter aortic valve replacement sizing is based upon computed tomography-derived annular measurements. There are a number of sizing algorithms for BAV based upon anatomical characteristics, often yielding different results. This is noted especially when a patient falls near the borderline between two valve sizes, an anatomical grey zone. Complementary to the algorithm approach is the use of pre-procedural patient-specific computer simulation using finite-element modelling. Case summary: An 86-year-old female was treated for heart failure secondary to severe and calcific BAV aortic stenosis with TAVR. Due to anatomical difficulty and grey-zone valve sizing, we demonstrate the use of pre-procedural patient-specific computer simulation with the novel Medtronic Evolut PRO+ platform to achieve a good result. Discussion: Using patient-specific computer simulation, we were able to safely select the valve and the deployment height and then accurately predict the result in a difficult, severely calcified BAV. In addition to improving outcome, this allows for patient-specific, tailored discussion to occur at heart team meetings.

Item Type: Article
Additional Information: © The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
Keywords: Bicuspid aortic valve, Case report, TAVR sizing
SGUL Research Institute / Research Centre: Academic Structure > Molecular and Clinical Sciences Research Institute (MCS)
Journal or Publication Title: Eur Heart J Case Rep
ISSN: 2514-2119
Language: eng
Dates:
DateEvent
October 2022Published
28 September 2022Published Online
21 September 2022Accepted
Publisher License: Creative Commons: Attribution-Noncommercial 4.0
PubMed ID: 36237228
Go to PubMed abstract
URI: https://openaccess.sgul.ac.uk/id/eprint/114919
Publisher's version: https://doi.org/10.1093/ehjcr/ytac398

Actions (login required)

Edit Item Edit Item