SORA

Advancing, promoting and sharing knowledge of health through excellence in teaching, clinical practice and research into the prevention and treatment of illness

Results of the Patient-Related Outcomes of Mechanical lead Extraction Techniques (PROMET) study: a multicentre retrospective study on advanced mechanical lead extraction techniques.

Starck, CT; Gonzalez, E; Al-Razzo, O; Mazzone, P; Delnoy, P-P; Breitenstein, A; Steffel, J; Eulert-Grehn, J; Lanmüller, P; Melillo, F; et al. Starck, CT; Gonzalez, E; Al-Razzo, O; Mazzone, P; Delnoy, P-P; Breitenstein, A; Steffel, J; Eulert-Grehn, J; Lanmüller, P; Melillo, F; Marzi, A; Sohal, M; Domenichini, G; Gallagher, MM (2020) Results of the Patient-Related Outcomes of Mechanical lead Extraction Techniques (PROMET) study: a multicentre retrospective study on advanced mechanical lead extraction techniques. Europace, 22 (7). pp. 1103-1110. ISSN 1532-2092 https://doi.org/10.1093/europace/euaa103
SGUL Authors: Gallagher, Mark Michael

[img]
Preview
PDF Published Version
Available under License Creative Commons Attribution Non-commercial.

Download (298kB) | Preview

Abstract

AIMS: Several large studies have documented the outcome of transvenous lead extraction (TLE), focusing on laser and mechanical methods. To date there has been no large series addressing the results obtained with rotational lead extraction tools. This retrospective multicentre study was designed to investigate the outcomes of mechanical and rotational techniques. METHODS AND RESULTS: Data were collected on a total of 2205 patients (age 66.0 ± 15.7 years) with 3849 leads targeted for extraction in six European lead extraction centres. The commonest indication was infection (46%). The targeted leads included 2879 pacemaker leads (74.8%), 949 implantable cardioverter-defibrillator leads (24.6%), and 21 leads for which details were unknown; 46.6% of leads were passive fixation leads. The median lead dwell time was 74 months [interquartile range (IQR) 41-112]. Clinical success was obtained in 97.0% of procedures, and complete extraction was achieved for 96.5% of leads. Major complications occurred in 22/2205 procedures (1%), with a peri-operative or procedure-related mortality rate of 4/2205 (0.18%). Minor complications occurred in 3.1% of procedures. A total of 1552 leads (in 992 patients) with a median dwell time of 106 months (IQR 66-145) were extracted using the Evolution rotational TLE tool. In this subgroup, complete success was obtained for 95.2% of leads with a procedural mortality rate of 0.4%. CONCLUSION: Patient outcomes in the PROMET study compare favourably with other large TLE trials, underlining the capability of rotational TLE tools and techniques to match laser methods in efficacy and surpass them in safety.

Item Type: Article
Additional Information: © The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com Correction available at https://doi.org/10.1093/europace/euaa267
Keywords: Complication, Evolution extraction sheath, Laser lead extraction, Rotational lead extraction, Technical success, Cardiovascular System & Hematology, 1103 Clinical Sciences
SGUL Research Institute / Research Centre: Academic Structure > Molecular and Clinical Sciences Research Institute (MCS)
Journal or Publication Title: Europace
ISSN: 1532-2092
Language: eng
Dates:
DateEvent
1 July 2020Published
23 May 2020Published Online
8 April 2020Accepted
Publisher License: Creative Commons: Attribution-Noncommercial 4.0
PubMed ID: 32447388
Go to PubMed abstract
URI: https://openaccess.sgul.ac.uk/id/eprint/112467
Publisher's version: https://doi.org/10.1093/europace/euaa103

Actions (login required)

Edit Item Edit Item