SORA

Advancing, promoting and sharing knowledge of health through excellence in teaching, clinical practice and research into the prevention and treatment of illness

Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.

Elbatran, AI; Li, A; Gallagher, MM; Kaba, R; Norman, M; Behr, ER; Sohal, M; Bajpai, A; Zuberi, Z; Saba, MM (2021) Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis. J Interv Card Electrophysiol, 60 (3). pp. 543-553. ISSN 1572-8595 https://doi.org/10.1007/s10840-020-00756-4
SGUL Authors: Behr, Elijah Raphael Saba, Magdi Mohamed

[img]
Preview
PDF Published Version
Available under License Creative Commons Attribution.

Download (452kB) | Preview

Abstract

PURPOSE: The effect of adding contact force (CF) sensing to 56-hole tip irrigation in ventricular arrhythmia (VA) ablation has not been previously studied. We aimed to compare outcomes with and without CF sensing in VA ablation using a 56-hole radiofrequency (RF) catheter. METHODS: A total of 164 patients who underwent first-time VA ablation using Thermocool SmartTouch Surround Flow (TC-STSF) catheter (Biosense-Webster, Diamond Bar, CA, USA) were propensity-matched in a 1:1 fashion to 164 patients who had first-time ablation using Thermocool Surround Flow (TC-SF) catheter. Patients were matched for age, gender, cardiac aetiology, ejection fraction and approach. Acute success, complications and long-term follow-up were compared. RESULTS: There was no difference between procedures utilising either TC-SF or TC-STSF in acute success (TC-SF: 134/164 (82%), TC-STSF: 141/164 (86%), p = 0.3), complications (TC-SF: 11/164 (6.7%), TC-STSF: 11/164 (6.7%), p = 1.0) or VA-free survival (TC-SF: mean arrhythmia-free survival time = 5.9 years, 95% CI = 5.4-6.4, TC-STSF: mean = 3.2 years, 95% CI = 3-3.5, log-rank p = 0.74). Fluoroscopy time was longer in normal hearts with TC-SF (19 min, IQR: 14-30) than TC-STSF (14 min, IQR: 8-25; p = 0.04). CONCLUSION: Both TC-SF and TC-STSF catheters are safe and effective in treating VAs. The use of CF sensing catheters did not improve safety or acute and long-term outcomes, but reduced fluoroscopy time in normal heart VA.

Item Type: Article
Additional Information: © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Keywords: Ablation, Complications, Contact force, Irrigated radiofrequency, Ventricular ectopy, Ventricular tachycardia, 1102 Cardiorespiratory Medicine and Haematology, Cardiovascular System & Hematology
SGUL Research Institute / Research Centre: Academic Structure > Molecular and Clinical Sciences Research Institute (MCS)
Journal or Publication Title: J Interv Card Electrophysiol
ISSN: 1572-8595
Language: eng
Dates:
DateEvent
April 2021Published
21 May 2020Published Online
25 March 2020Accepted
Publisher License: Creative Commons: Attribution 4.0
PubMed ID: 32440943
Go to PubMed abstract
URI: https://openaccess.sgul.ac.uk/id/eprint/111977
Publisher's version: https://doi.org/10.1007/s10840-020-00756-4

Actions (login required)

Edit Item Edit Item